Wait! Don’t Go Yet! 👋

We see you eyeing those adorable outfits! 😍 Before you leave, here’s 10% OFF your first order!

Hurry, your little one’s next favorite outfit is waiting! 🛍️✨

Online UPS Mac Gold Series 10 KVA to 30 KVA

True Online Double-Conversion UPS with 3 Phase Input Capability

The MAC Online UPS Mac Gold Series is a true online double-conversion UPS in tower configuration with an in-built galvanic isolation transformer. Galvanic isolation is recommended for all critical IT applications and is especially useful for installations at sites with poor power conditions and weak neutral.

The MAC UPS with in-built galvanic isolation acts as a barrier to raw mains power quality problems and provides clean, uninterrupted power to critical loads. MAC UPS systems are designed for both short and long backup time requirements with the addition of external batteries. An in-built high-capacity charger shortens the recharging period and increases system availability.

  • Premium Quality
  • Secure Payments
  • Satisfaction Guarantee
  • All over India Shipping
Share your love
Guaranteed Safe Checkout

ISO 9001:2015 | ISO 14001:2015 | ISO 45001:2018 | RoHS Certified

Online UPS Mac Gold Series - Premium Power Protection

3 Phase Input & 1 Phase Output with I.G.B.T. Technology

Capacity Range: 10 KVA to 30 KVA | Galvanic Isolation Technology

20+ Years of Excellence | Three Phase Input Flexibility | Zero Transfer Time

True Online Double-Conversion UPS with Galvanic Isolation

3 Phase Input Power

Three phase input (380/400/415V) for higher capacity loads with single phase output flexibility

I.G.B.T. Technology

Advanced IGBT-based design ensures high efficiency (≥92%) with pure sine wave output

Premium Gold Series

Premium quality construction with superior components for mission-critical applications

Redundancy Ready

Supports hot standby and parallel redundancy for maximum uptime

Salient Features - Online UPS N Series

Performance Features

High inverter efficiency (≥92%)
Pure sine wave output
Fast transient response
Handles higher crest factor (4:1)
Low total harmonic distortion (≤2%)

Operational Features

Low acoustic noise (less than 55 dB)
Automatic bypass provided
Manual bypass switch (optional)
Generator compatible
Auto-sensing frequency (50/60Hz ±3%)

Special Technology

Hot standby capability
Parallel redundancy support
Tower configuration
Standalone operation
Communication: RS232/USB/RS485/SNMP

Protection Features

Protection against RFI & EMI
Overload capacity: 110% for 10 min
Over voltage & under voltage protection
Short circuit protection
Battery output breaker

Technical Specifications - Online UPS Mac Gold Series

3 Phase Input – 1 Phase Output | I.G.B.T. Technology | Generator Compatible

⚙️ Capacity & Configuration

Parameter 10 KVA 12 KVA 15 KVA 20 KVA 25 KVA 30 KVA
Systems Voltage (DC Bus) 180-240V 192-240V 192-240V 240-384V 240-384V 360-384V
Configuration: Standalone Tower Configuration, On-line double conversion with IGBT technology & pure Sine wave PWM; Generator compatible

🔌 Input Specifications

Parameter Specification
Phase3 Phase AC
Normal Voltage380/400/415 V
SourceMains / D.G. set (Generator Compatible)
Frequency50/60Hz ± 3% (Suitable for Generators), Auto Sensing
Power Factor≥0.92

⚡ Output Specifications

Parameter Specification
PhaseSingle Phase
Voltage220/230/240 VAC ± 1% (Adjustable)
Frequency50 Hz
Power Factor0.9 p.f.
Total Harmonic Distortion (THDv)≤ 2% (Linear Load), ≤ 5% (Non Linear Load)
Wave FormPure Sine Wave
Transient Response< 8% (10% ~ 90% Linear Load)%
Voltage Harmonic≤3 (resistive Load)%

📊 Performance Specifications

Parameter Specification
Overload Capacity110% for 10 Minutes & 125% for 01 Minute
Crest Factor4:1
Transfer Time0 (Zero - True Online Operation)
Efficiency (AC-AC)≥92% (Full Load)
LED DisplayProvided
LCD DisplayInput & Output Voltage, Frequency & Current # DC Voltage # Charging & Discharging Current, Battery Low

🌡️ Environmental Specifications

Parameter Specification
Operating Temperature0-45°C (Continues)
Storage Temperature0-60°C
Humidity10-90% (Non Condensing)
Audible Noise Level< 55 dB at full load unto distance of 1 mtr (low noise)
IP RatingIP20

🔋 Battery & Protection

Parameter Specification
BackupAs per Customer requirement
Internal BatteryNot Applicable (External Battery Bank Required)
Battery MakeCustomer Choice
Rack / CablesIron Made with Silver/black paint and interconnecting cables
Recharge Time4-5 hours for 90% of full capacity
Battery Output BreakerProvided
Manual Bypass SwitchOptional
Automatic BypassProvided
Emergency TripOptional
Equipment CoolingSuitable capacity fans for air circulation in the UPS systems
ProtectionOver voltage, short circuit, overload at UPS terminal, Under voltage at battery terminal & overshoot and undershoot is greater than 4% of rated voltage for duration of 40m sec max

📡 Communication & Warranty

Parameter Specification
CommunicationRS232/USB/RS485/SNMP
Battery Warranty2 year comprehensive onsite warranty from the date of successful installation
UPS Warranty01 year onsite comprehensive from the date of successful installation
SupportManufacturer's have adequate manpower & infrastructure to support the maintenance after sales service on site
Quality CertificationISO 9001:2015, ISO 14001:2015, ISO 45001:2018, RoHS, CE Certification
The certifying body is accredited by National Accreditation Board for Certification Bodies (NABCB)

Why Choose MAC Power Systems Online UPS?

Galvanic Isolation

Built-in isolation transformer provides complete protection against electrical noise and power quality issues

ISO Certified

ISO 9001, ISO 14001, ISO 45001, RoHS & CE compliant manufacturing

Premium Gold Series

Premium quality construction with superior components for mission-critical applications requiring 10-30 KVA

I.G.B.T. Technology

Advanced IGBT-based design for superior efficiency (≥92%) and pure sine wave output

Hot Standby & Redundancy

Supports hot standby and parallel redundancy for mission-critical applications

3 Phase Input Power

Three phase input capability (380/400/415V) for higher capacity loads with stable single phase output

Frequently Asked Questions - Online UPS Mac Gold Series

What is the advantage of 3 phase input UPS over single phase?
Three phase input UPS systems like the Mac Gold Series can handle higher power loads (10-30 KVA) more efficiently than single phase systems. The three phase input distributes the load across three phases, reducing current per phase and minimizing cable sizes. It's ideal for large commercial installations, data centers, and industrial facilities requiring high-capacity power protection with single phase output for IT equipment.
Why is this called the "Mac Gold Series"?
The Mac Gold Series represents our premium line of industrial-grade UPS systems with superior build quality, advanced features, and enhanced reliability. These systems use premium-grade components, offer extended operational life, and include advanced features like hot standby and parallel redundancy. They're designed for mission-critical applications where power quality and uptime are paramount.
Can this UPS work with a 3 phase generator?
Yes, the Mac Gold Series is fully compatible with 3 phase diesel generators. It features auto-sensing frequency (50/60Hz ±3%) and can handle the voltage and frequency variations typically encountered with generator power. This makes it ideal for locations with unreliable grid power or facilities that rely on backup generators.
What capacity do I need for my data center?
The required capacity depends on your total IT load including servers, storage, networking equipment, and cooling systems. The Mac Gold Series offers 10-30 KVA models. As a general guideline, calculate your total load in KW and divide by the power factor (0.9) to get required KVA. We recommend adding 20-30% headroom for future expansion. Our technical team can help you calculate the exact requirement based on your specific setup.
Can multiple units be connected for redundancy?
Yes, the Mac Gold Series supports both hot standby and parallel redundancy configurations. In hot standby mode, a backup UPS automatically takes over if the primary unit fails. In parallel redundancy, multiple UPS units share the load, providing N+1 or N+N redundancy for maximum uptime. This is essential for data centers and mission-critical facilities that cannot afford any downtime.
What backup time can I expect?
Backup time depends entirely on your external battery bank capacity and connected load. The Mac Gold Series requires external batteries (no internal batteries). With proper battery sizing, you can achieve backup times from 15 minutes to several hours. The high-capacity charger recharges batteries to 90% capacity in just 4-5 hours. Contact our team for battery sizing calculations based on your desired backup time and load.

Reviews

There are no reviews yet.

Be the first to review “Online UPS Mac Gold Series 10 KVA to 30 KVA”

Your email address will not be published. Required fields are marked *

Advanced Power Solutions

Engineered battery chargers, UPS systems, and stabilizers designed for industrial and critical applications.

Reliable Battery Charging Systems

High-performance railway, telecom, and substation battery chargers with long service life and safety compliance.

Industrial-Grade Manufacturing

Robust design, quality-tested components, and strict quality control to ensure dependable performance in harsh environments.

Technical Support & Custom Solutions

Expert consultation, installation guidance, and customized power solutions tailored to your project requirements.